Hantek DSO 1200 200MHz Handheld Oscilloscope with Digital Multimeter
The DSO1200 functions both as a two channel digital 200 MHz oscilloscope, or a digital multimeter. The DSO1200 comes with oscilloscope probes and multimeter probes. With its intuitive and familiar controls makes the DSO1200 very easy to work with, making setup up quick easy. The multimeter has Voltage, Current, Resistance, and Capacitance ranges, and it also checks diodes and continuity. This oscilloscope comes with a 3500 mAH lithium ion battery.
The DSO-1200 can be attached to your PC with software that comes in the package. A carrying case with a shoulder strap is included with the scopemeter unit, the two types of probes, the AC power adapter, USB cable, Manual, and the software CD.
- Excellent Industrial Design .Direct key for Each Channel ,Time base ,Trigger and Digital Multimeter, easy to operate.
- Large 5.7 inch TFT Color LCD Display ,Led backlight,Display clearly.
- USB Host/Device 2.0 full-speed interface ,support removable disk, RS-232/LAN Optional ,Easy to control by PC or long-distance.
- High Bandwidth 600MHz+ 6000 COUNTS high precision Digital Multimeter (DMM).
- High refresh rateCHigh Real-time Sample Rate 500MS/s, 50GS/s Equivalent-time Sample Rate.
- FFT , + , - , * , / ,X-Y, 22 kinds of auto measurements, PASS/FAIL Check ,easy to use on production line.
- Multiform Trigger mode ,2 separate Time Base in ALT Trigger mode ,easy to see 2 signal with different frequency.
- 1000 waveforms save and record.
- Battery Power Operation (Installed) Industrial Design.
- Save waveform in the following: jpg/bmp graphic file, MS excel/word file. Dimensions (mm):240(L)x165(W)x50(H), be carried easily.
- Labview\VB\VC Second Design instance.
- Vertical Mode:
- Channels: 2
- Bandwidth: 200MHz
- Rise Time: 1.7ns
- Input Impedance:
- Resistance: 1MΩ
- Capacitance: 15 pF
- Input Sensitivity: 10mV/div to 5V/div
- Input Coupling: AC, DC and GND
- Vertical Resolution: 8 bits
- Maximum Input: 400V (DC+AC Peak)
- Horizontal Mode:
- Real-Time Sampling Rate: 500MSa/s
- Equivalent Sampling Rate: 50GSa/S
- Time Base Range: 5ns/div~1000s/div
- Memory Depth:
- 32k at Single Channel
- 16k at Dual Channel
- Time Base Precision: ±50ppm
- Trigger Mode:
- Source: CH1, CH2
- Mode: Edge,Video, Pulse Width, Alternative
- X-Y Mode:
- X-Axis Input: Channel 1
- Y-Axis Input: Channel 2
- Phrase Shift: Max.3 degree
- Cursors & Measurement
- Voltage Measurement: Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot
- Time Measurement: Frequency,Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
- Delay Measurement:
- Delay time from ch1 rising edge to ch2 rising edge
- Delay time from ch1 falling edge to ch2 falling edge
- Cursors Measurement: Manual, Track, Auto Measure Modes
- Waveform Signal Process: CH1+/- CH2, CH1xCH2, CH1/CH2, FFT, Invert
- Storage: 15 Waveforms and Setups
- Meter Mode:
- Maximum Resolution: 6,000 Counts
- DMM Testing Modes: Voltage, Current, Resistance, Capacitance,Diode & Continuity
- Maximum Input Voltage: AC: 600V, DC: 800V
- Maximum Input Current: AC: 10A, DC: 10A
- Input Impedance: 10 MΩ
.