Kyoritsu 3128 High Voltage Insulation Tester
With 6 different ranges, the Kyoritsu 3128 High Voltage Insulation Tester can be operated by the built-in rechargeable battery or an AC line.
• Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions.
• Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc.
• 6 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 12000V
• Fine adjustment of voltage setting at each range is also possible
• Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight.
• Automatic discharge after test with monitoring of the discharge voltage.
• Internal memory can store about 43,000 data (max).
• Robust design for field use with IP64 rating (with lid closed).
INSULATION RESISTANCE
(*): Accuracy is not guaranteed with setting of 250V or less
Rated voltage : 500V
• Max measurement value : 500G?
• Accuracy: 400k~50G? ±5%rdg±3dgt(*), 50G~500G?±20%rdg(*)
• Short circuit current : Max 5.0mA
• Load resistor to output rated voltage : 0.5M? or more
Rated voltage : 1000V
• Max measurement value : 1T?
• Accuracy: 800k~100G? ±5%rdg±3dgt, 100G~1T? ±20%rdg
• Short circuit current : Max 5.0mA
• Load resistor to output rated voltage : 1M? or more
Rated voltage : 2500V
• Max measurement value : 2.5T?
• Accuracy: 2M~250G? ±5%rdg±3dgt, 250G~2.5T? ±20%rdg
• Short circuit current : Max 5.0mA
• Load resistor to output rated voltage : 2.5M? or more
Rated voltage : 5000V
• Max measurement value : 5T?
• Accuracy: 4M~500G? ±5%rdg±3dgt, 500G~5T? ±20%rdg
• Short circuit current : Max 5.0mA
• Load resistor to output rated voltage : 5M? or more
Rated voltage : 10000V/12000V
• Max measurement value : 35T?
• Accuracy: 8M~1T? ±5%rdg±3dgt, 1T~10T? ±20%rdg
• 10T~35T? Values are displayed, but accuracy isn't guaranteed
• Short circuit current : Max 5.0mA
• Load resistor to output rated voltage : 20M? or more/24M? or more
OUTPUT VOLTAGE
• Rated voltage : 500V/ 1000V
• Monitor accuracy : ±10%±20V/ ±10%±20V
• Output accuracy : 0~+20%/ 0~+10%
• Selectable range : 50~600V(in steps of 5V)/ 610~1200V(in steps of 10V)
• Rated voltage : 2500V/ 5000V
• Monitor accuracy : ±10%±20V/ ±10%±20V
• Output accuracy : 0~+10%/ 0~+10%
• Selectable range :1225~3000V(in steps of 25V)/ 3050~6000V(in steps of 50V)
• Rated voltage : 10000V/ 12000V
• Monitor accuracy : ±10%±20V/ ±10%±20V
• Output accuracy : -5~+5%/ -5~+5%
• Selectable range : 6100~10000V(in steps of 100V)/ 10100~12000V(in steps of 100V)
Withstand voltage :
• AC8770V : between line terminal and enclosure / 5sec (50/60Hz)
• AC6880V : between the measuring terminal and enclosure / 5sec (50/60Hz)
• AC2330V : between the power connector and enclosure / 5sec (50/60Hz)
Operating temperature & humidity range
• -10°C~50°C /Relative humidity 85% or less (when operating with an external power supply, no condensation)
• 0°C~40°C /Relative humidity 85% or less (when operating with battery, no condensation)
Storage temperature & humidity range : -20°C~60°C / Relative humidity 75% or less (no condensation)
Applicable standards
• IEC 61010-1 CAT.IV 600V Pollution degree 2,
• IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed.
Power source:
• Rechargeable Lead storage battery (12V)*
• Charging time: approx. 8 hours / AC Power supply (100V~240V, 50/60Hz)
• *Continuous measuring time: approx. 4 hours
• (a load of 100M? at the Insulation resistance 12000V Range.)
• approx. 2 hours
• (Max current consumption in range while rated currents are maintained.)
• Dimension : 330 (L) x 410 (W) x 180 (D) mm *Instrument and Hard case
• Weight: 9kg approx. (including battery) *Instrument and Hard case
• Accessories:
• 7170 (Main cord), 7224A (Earth cord), 7225A (Guard cord), 7226A (Line probe), 7227A (Line probe with alligator clip), 8029 (Extension prod),
• 8212-USB-W (USB adaptor with KEW Windows (Software)),
• Instruction manual, Calibration Certificate
• Instruction manual, Calibration Certificate
• Optional: 7254 (Longer Line probe with alligator clip)